Comprehensive Safety Performance Tester
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction
This product series is primarily suited for various types of household appliances, small appliance production lines, and laboratories.
Test Item
AC withstand voltage, DC withstand voltage (optional), insulation resistance, grounding resistance, leakage current, no-load power
All instruments in this series come standard with a PLC, RS-232, and an alarm light interface.
Select accessories
Alarm light, foot switch, matching variable-frequency power supply, industrial computer, system control software
Size 435W×134.8H×550D
Key Features
- 5.7-inch LCD display with a blue background, providing intuitive and clear data visualization.
- Meets the general electrical safety standards and specifications of CCC, IEC, EN, VDE, BS, GS, UL, and others.
- By optionally equipping the system with an industrial computer and adding a barcode scanner, automated control and data entry can be achieved, enabling the construction of a production data management platform that can be integrated into the enterprise production management system.
- Optional variable-frequency power supply, integrated into an automated test system, enables automatic adjustment of the test power output without manual intervention, ensuring the accuracy of test results.
- Optional USB data interface for unlimited storage of test conditions and results.
- Up to 100 sets of test conditions can be stored, with 8 test steps per set; each set can be individually configured with specifications and model numbers for easy retrieval.
- High speed: The test instrument’s control core is powered by a high‑speed ARM processor, enabling rapid and comprehensive data processing; standard test procedures can be completed in as little as 8 seconds.
- High accuracy: Safety compliance testing achieves an accuracy of up to 3%.
- The withstand voltage can be set to ramp up or ramp down, with upper and lower limit alarm functions.
- A digital closed-loop feedback control scheme and fully automatic voltage regulation ensure that the output voltage and current are automatically corrected, remaining unaffected by external grid fluctuations and thereby guaranteeing test accuracy.
- The grounding resistance test can be configured to use either voltage‑based or resistance‑based judgment modes, meeting the requirements of various national and industry standards.
Technical Specifications:
| Model number | LK9661 |
| Test Item | AC withstand voltage, DC withstand voltage (optional), insulation resistance, grounding resistance, leakage resistance, no-load power |
| Data storage method | USB Storage (Optional) – Model LK9661A |
| Built-in power supply | None (Leakage and power tests are conducted using an external test power supply) |
| AC withstand voltage | |
| Output Voltage Setting Range/Accuracy | AC 200~5000V ±(3%×set value + 5 digits) |
| Breakdown current measurement range/accuracy | 0.10~25.00 mA ±(3%×reading + 5 digits) |
| Breakdown Current Preset Alarm Range | Upper limit: 0.10–25.00 mA; Lower limit: 0.00–5.00 mA |
| Test Time Range/Resolution | 1–300 s, 1 s/step |
| Arc Detection | Optional, levels 1–9 (level 9 is the highest sensitivity) |
| DC Withstand Voltage (LK9661D) | |
| Output Voltage Setting Range/Accuracy | DC 200~5000V ±(3%×set value + 5 digits) |
| Breakdown current measurement range/accuracy | 0.10~10.00 mA ±(3%×reading + 5 digits) |
| Breakdown Current Preset Alarm Range | 0.10~10.00mA |
| Insulation resistance | |
| Output Voltage Setting Range/Accuracy | DC 500/1000 V ± (3% × reading + 5 digits) |
| Insulation Resistance Measurement Range/Accuracy | 1~2000 MΩ ≤ 100 MΩ: ±(5% × reading + 3 digits) > 100 MΩ: ±(8% × reading + 8 digits) |
| Insulation Resistance Alarm Setting Range | Upper limit: 0–2000 MΩ; Lower limit: 1–2000 MΩ |
| Test Time Range/Resolution | 1–300 s, 1 s/step |
| Ground resistance | |
| Ground Current Output Range/Accuracy | AC 5.0~32.0A ± (3% × set value + 5 digits) |
| Ground Resistance Measurement Range/Accuracy | 10.0~600 mΩ ±(3% × reading + 5 digits) |
| Ground Resistance Alarm Setting Range | Upper limit: 5–10 A: 10.0–600 mΩ; 11–25 A: 10.0–300 mΩ; 26–30 A: 10.0–200 mΩ; Lower limit: 0.0–100 mΩ |
| Test Time Range/Resolution | 1–60 seconds, 1 second per step |
| Leakage current | |
| Output voltage | 1.06 times the rated voltage (externally supplied) |
| Leak Type Configuration | Dynamic leakage, static leakage; optionally equipped with three built-in human body networks for seamless switching, and customizable to any human body network. |
| Output Voltage Measurement Range/Accuracy | AC 50~280V ±(0.5%×reading + 2 digits) |
| Leakage Current Measurement Range/Accuracy | 0.05~20.00 mA ±(3%×reading + 10 μA) |
| Leakage current set alarm range | Upper limit: 0.05–20.00 mA; Lower limit: 0.01–5.00 mA |
| Test Time Range | 1–300 s, 1 s/step |
| No-load power | |
| Output voltage | 1.0 times the input voltage (externally supplied) |
| Output Voltage Setting Range/Accuracy | AC 50~280V ±(0.5%×reading + 2 digits) |
| Output current measurement range/accuracy | AC 0.20~30.00 A ±(0.5%×reading + 2 digits) |
| Power measurement range/accuracy | 30~6000W ±(0.5%×reading + 5 digits) |
| Power Setpoint Alarm Range | Upper limit: 30,000,000–60,000,000; Lower limit: 0–60,000,000 |
| Test Time Range/Resolution | 1–300 s, 1 s/step |
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords:
Comprehensive Safety Performance Tester