LB-2609 Fully Automatic Optical Contact Angle Meter for Measuring Water Droplet Contact Angles
Category:
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
The contact angle of a water droplet is defined as the angle formed at the three-phase junction of solid–liquid–gas, between the liquid–gas interface and the solid–liquid interface. The contact angle serves as an indicator of the wettability of a solid surface; it is typically measured using droplets of most common liquids. A low contact angle signifies high wettability (hydrophilic) and easy adhesion to the surface, whereas a high contact angle indicates hydrophobicity, often associated with significant organic contamination or poor surface adhesion. The contact angle of a liquid in contact with a flat solid surface is determined by measuring the angle between the liquid–solid–gas triple point—specifically, the endpoint of the droplet’s meniscus and its point of contact with the solid surface—thus providing insight into surface cleanliness. In summary, the contact angle is a key metric for assessing the wettability of a solid surface; it is commonly evaluated using droplets of typical liquids. A low contact angle reflects high wettability (either hydrophilic or hydrophobic) and low surface energy.
Contact angle meters are used to measure the wettability of liquids on solid surfaces. By determining the contact angle, they enable the calculation of parameters such as the solid’s surface free energy and the liquid’s surface tension. These instruments find broad applications in industries including petroleum, chemical engineering, pharmaceuticals, papermaking, and dyeing, and are also well suited for scientific research and educational purposes. Our factory offers a comprehensive range of contact angle meter products—indigenously developed, featuring cutting-edge technology, assured quality, and robust software functionality. We can provide models tailored to meet diverse user requirements.
Product Features:
1. In accordance with the standard, design the instrument’s structure according to the specified criteria (injection needle: 0.51 mm; injection accuracy: 0.1 µL).
2. Use the appropriate measurement method according to the standard: for angles below 20°, employ the width‑height method; for angles between 20° and 120°, use the elliptical method. This helps prevent excessive measurement errors caused by selecting the wrong method. (Currently, manufacturers in Guangdong only use the ring‑method, which results in significant deviations and is not compliant with standards.)
3. Equipped with testing capabilities for curved‑surface angles, concave‑convex angles, and approach/retract angles, ensuring the instrument remains compatible even as customers update their products. For example, future touchscreens may feature curved surfaces.
4. Utilizing industrial-grade light sources and precise algorithms, this solution eliminates wavelength drift while enabling accurate measurements at angles between 2° and 10°. (Currently, instruments on the market suffer from unstable light wavelengths, making it impossible to acquire images below 10° and thus hindering testing.)
Instrument Composition and Functional Overview:
This instrument is manufactured using state-of-the-art technology. It features a dedicated CMOS digital camera, paired with a high‑resolution continuous zoom microscope and a bright, highly stable industrial light source. Equipped with a three‑dimensional sample stage that enables precise vertical, horizontal, and longitudinal movements, it supports micro‑volume sampling and fine adjustments in all directions. Additionally, the design incorporates an extendable‑rod worktable, making it adaptable to applications involving materials of varying thicknesses. The instrument’s frame can be adjusted to suit samples of different sizes, thereby broadening its range of use. The accompanying software includes correction functions, allowing test results from multiple measurements to be saved within a single report, facilitating more effective management and analysis of material data. With its elegant, user‑friendly design, this instrument meets the needs of users across a wide variety of industries requiring contact‑angle measurements.
Technical Specifications:
| Parameter Category | Parameter content |
| Contact angle measurement range | 0–180 degrees |
| Contact angle resolution accuracy | ±0.10° |
| Contact Angle Measurement Method | Sessile drop method |
| Contact Angle Analysis Method | Manual horizontal measurement, manual slope measurement, automatic width‑height measurement (standard test method for plane angles below 20°), manual tangent‑line method, automatic ellipse‑fitting method (standard test method for plane angles between 20° and 120°), and curve‑fitting method (specifically for testing irregular and curved products). |
| Optical lens | 2X Fixed-Magnification High-Definition Microscope |
| Camera module | Digital CMOS camera |
| Droplet application method | Manual droplet application |
| Liquid precision | 0.01ul |
| Image Functionality | Video recording / Playback, instant screenshots, and export of any single frame from the video as an image. |
| Worktop dimensions | 100mm×120mm |
| Workbench movement | 50 mm up and down, 50 mm left and right, 30 mm front and back |
| Telescopic up-and-down workbench | 30mm |
| Workbench fixed plate movement | Front and rear 150mm |
| Sampler movement | 100 mm up and down, 100 mm left and right |
| Microscope movement | Front and rear: 80 mm (fine adjustment: 3 mm) |
| Specimen dimensions | 210 mm (width) × 80 mm (thickness) × 280 mm (length) |
| Instrument external dimensions | 320 mm (width) × 530 mm (length) × 430 mm (height) |
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords: