Product Introduction
The fully automatic concrete impermeability tester features a 7-inch touch-screen display and connects to a large LCD via the TCPMobuds standard protocol, providing an intuitive overview of each device’s operating and testing status. Concrete durability has long been a key concern for material engineers and structural designers, as it directly impacts the safety of both daily life and industrial operations. Consequently, research into impermeability‑testing methods—key indicators of durability—has become increasingly vital. Beyond being time‑consuming and inefficient, the primary challenge in concrete impermeability testing lies in the sheer volume of specimens required. To meet the needs of a broad customer base, we have introduced new models: one set of six specimens, two sets of twelve, and six sets of thirty-six, all fully automated. These systems require no application of sealing compounds; they automatically seal, pressurize, maintain constant pressure, time the test, detect leaks, record data, demold the specimens, and provide real-time monitoring, thereby ensuring a cleaner testing environment.
Fully automatic concrete permeability testing equipment—intelligent, easy to operate, with stable performance and reliable results. It can accommodate up to 36 test specimens per run, customizable to suit your needs. Each test group is independently controlled, ensuring no interference between tests.
Reference standard:
GB/T 50082-2024 “Standard for Test Methods of Long-Term Performance and Durability of Concrete”
JG/T 249-2009 “Concrete Impermeability Tester”
JTS/T 236-2019 “Technical Specifications for Concrete Testing and Inspection in Water Transport Engineering”
T0528-1994 “Test Method for Impermeability of Concrete” JTJ270-1998 “Code for Concrete Testing in Water Transport Engineering”
Technical Specifications:
| Project | Specific parameters |
| Test pressure pressurization method | Bottom-up pressurization |
| Relative error of the testing machine’s indicated value | ≤0.05 MPa |
| Test pressure resolution accuracy | 0.01MPa |
| Error in maintaining the test pressure value | Stepwise pressurization method: ±0.05 MPa; Permeation height method: ±0.05 MPa |
| Maximum pressure of the testing machine | 1.2MPa |
| Touchscreen display | It features a 7-inch microcomputer touch screen for test operation and status display. |
| Specimen dimensions | φ175*185*150mm |
| Test modulus | Can accommodate 6 specimens (independent measurement and control, independent judgment) |
| Test Data Query | It can automatically generate test reports, upload data to the user’s testing platform system, and customize report templates. |
| Internet connectivity | RS485, RS232 data upload |
| Power | ≤300W |
| External dimensions | 1725×675×570mm |
| Power supply | 220V50Hz |
- Operation interface
- Welcome Screen
[Enter Anywhere] Click here to access the main menu.
[Time Display] Press and hold here for 3 seconds to enter the system time settings screen, where you can set the system time.
- Main Menu
[Automatic Mode] Enter the automatic mode test interface and switch the test mode to Automatic.
[Manual Mode] Enter the manual mode test interface, and switch the test mode to automatic.
[Test Method Selection] Enter the test method selection interface and switch between the stepwise pressurization method and the high-pressure method.
[View] Enter the test results viewing interface to access historical test records.
[Calibration] Enter the system calibration interface and perform pressure calibration.
[Settings] Enter the system parameter settings interface to configure the system’s allowable parameters.
- Test Method Interface
[Select the Stepwise Pressurization Method] Set the initial pressure, increase the pressurization time incrementally, and specify the final water pressure (the final water pressure is set by adding one pressure level to the installed impermeability grade).
[Water Seepage Height Method] Set the seepage pressure and seepage duration (holding time).
- Automatic Mode Interface:
[Group 1] [Group 2]
[Water Pressure] Displays the real-time water pressure value.
[Test Time] Displays the test time (00:00:00).
[Test Status] The test status is displayed as “Test Stopped.”
[Drainage] Perform the drainage action.
[Start] Begin the test procedure. [Stop] Stop the test procedure.
[Protection Status] The protection status is displayed as Idle, Overpressure, or Pump Running Time Too Long.
[Entrustment Officer] Trial Information Entry Officer.
[Sample Number] Enter the sample number in the test information field.
[Waterproofing Grade] Enter the waterproofing grade in the test information.
[Operator] Enter the operator’s name for test information.
[Age Period] Enter age period
- Settings
[Water Pressure Protection Value] Water pressure protection setpoint (this setting is generally left unchanged); factory default: 1.3.
[Pump Protection Time] Pump protection time setting: Factory default value is 2.
[Leak Detection Time] Leak detection time setting (leak‑detection buffer time), default value: 0.1.
[Drain Time] Water discharge time: Factory default value 120
[Pump Jog Start Time] The time it takes for the pump to start when the water pressure reaches the set value. Factory default: 2.
[Pump Jog-Stop Time] The time it takes for the pump to shut down when the water pressure reaches the set value. Factory default: 3.
- Manual mode
[Group 1] [Group 2]
[Current Water Pressure] Displays the real-time value of the current water pressure.
[Set Water Pressure] Set the target water pressure value for the test.
[Pump 1 & 2] Start the booster pumps: Group 1 starts Pump No. 1, and Group 2 starts Pumps No. 1 and No. 2.
[Water Valve] The control valve for each test mold.
- Test results
[Group 1] [Group 2]
[Upload] Upload the test results of this group via the corresponding communication protocol (RS485 or Ethernet).
[Previous Page] Displays the previous set of results for the current group.
[Next Page] Displays the next group in the current set.
- Calibration Interface
[Real-Time Pressure Value] Displays the real-time water pressure and sealing values.
[Real-time Code Value] Displays the real-time code values for water pressure and sealing.
[Zero-point Code Value] The code value corresponding to a real-time value of zero.
[Calibration Force Value] Set the value for the calibration point.
[Calibration Code Value] The code value corresponding to the setpoint when the real-time value equals the setpoint.
[Zeroing] Perform the zeroing operation.
[Pressurization] Perform the pressurization operation.
[Calibration] Perform the calibration procedure.
[Pump and drain valves, water valves No. 1–6] perform pressure-related operations.
[Calibration Procedure] Tap when setting the water pressure value.
Wiring diagram
Related Product
HC-40 Concrete Multi-functional Strength Tester
The HC-40 concrete multi-functional strength tester is a high-performance testing device integrating multiple advanced technologies, specifically designed for evaluating the strength and quality of concrete.
FAQs
Customer Reviews
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.