Pointer-type vernier caliper with open‑type single‑direction claw jaws (long‑reach extended claws)
Category:
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
The open‑type, single‑jaw caliper features an open‑frame design and a unidirectional jaw, specifically engineered to measure the outer diameter, thickness, and other dimensions of large, elongated workpieces. Its body is crafted from stainless steel, offering excellent rigidity, wear resistance, clear graduations, smooth sliding action, and stable measurements.
The open‑frame design facilitates cleaning and maintenance, making it well suited to harsh workshop environments. The single‑direction long jaws can reach deep into workpieces or measure at remote locations, addressing measurement scenarios that conventional calipers cannot access. Equipped with a locking mechanism, it allows readings to be secured for convenient re‑inspection and record‑keeping.
Product Applications:
It is widely used for large‑size, long‑distance, and deep‑dimensional measurements in industries such as machining, mold making, hardware, pipe manufacturing, and sheet metal fabrication.
Technical Specifications:
| Parameter | Specification Description |
| Range | 0–500 mm, 0–600 mm, 0–1000 mm |
| Graduation value | 0.02mm |
| Accuracy | ±0.05 mm (for a range of 0–500 mm) |
| Main material | Stainless steel |
| Scale craftsmanship | Laser scale |
| Applicable temperature | 0–40℃ |
The reading principle of a vernier caliper:
The reading mechanism of a vernier caliper consists of a main scale and a vernier scale. When the movable jaws are brought into contact with the fixed jaws, the “0” mark on the vernier scale aligns with the “0” mark on the main scale, at which point the distance between the jaws is zero. As the slide is moved to the left to a certain position, the distance between the fixed and movable jaws corresponds to the measured dimension of the part. The integer portion of the dimension can be read from the main‑scale markings to the right of the vernier’s zero line, while the fractional part—less than 1 mm—can be determined by reading the vernier scale.
How to read a vernier caliper:
The reading of a vernier caliper consists of the integer part in millimeters and the decimal fraction in millimeters. The method for taking the reading is as follows:
(1) Integer part: Starting from the first graduation line on the main scale to the left of the vernier zero mark, read the integer portion in millimeters.
(2) Decimal part: The decimal portion in millimeters is obtained by multiplying the number of scale divisions on the vernier scale that align with a particular division on the main scale by the instrument’s least count. If no vernier scale division exactly coincides with a main‑scale division, and the reading falls between two values—one larger and one smaller—take the average of the corresponding least‑count increments.
(3) Determine the measured value by addition: Add the integer part of the millimeter measurement to its decimal part; the result is the measured dimension of the workpiece.
| Measurement range mm | Division value mm | Indication/week mm | Accuracy mm | L mm | a mm | d mm | e mm | f mm |
| 0-500 | 0.02 | 2 | ±0.05 | 650 | 90 | 21 | 10 | 18 |
| 10-500 | 0.02 | 2 | ±0.05 | 650 | 90 | 21 | 5 | 18 |
| 10-600 | 0.02 | 2 | ±0.05 | 750 | 90 | 21 | 5 | 18 |
| 0-600 | 0.02 | 2 | ±0.05 | 750 | 90 | 21 | 10 | 18 |
| 0-1000 | 0.02 | 2 | ±0.07 | 1190 | 150 | 28 | 10 | 24 |
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords:
Pointer-type vernier caliper with open‑type single‑direction claw jaws (long‑reach extended claws)