SYA-90 Building Material Flame-Retardancy Testing Machine
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
The building material flame‑retardancy testing machine is an experimental instrument manufactured in accordance with GB/T 8625‑2026, “Test Methods for Flame Retardancy of Building Materials.” It is used to determine whether a building material exhibits combustibility. Any material that passes the furnace test and meets the requirements of the building material flammability test may be classified as a flame‑retardant building material.
Product Features:
1. Employs microcomputer control, with a high degree of automation;
2. During furnace wall temperature preheating, the temperature level is displayed quite intuitively;
3. The solenoid valve is connected to the combustible gas and controlled by a microcomputer; when the flue gas temperature exceeds 200°C, the program automatically shuts off the solenoid valve, ensuring safe and reliable operation.
4. Equipped with a high-power constant-temperature, constant-current unit, offering rapid temperature stabilization and precise flow control.
5. A wind speed sensor is used to monitor airflow in real time and display the results digitally.
Technical Specifications:
| Parameter Category | Parameter content |
| External dimensions of the shaft furnace | 1020mm×1020mm×3930mm |
| Combustion chamber dimensions | 800mm×800mm×2000mm |
| Test bracket dimensions | 380mm×380mm×1000mm |
| Flue specifications and alarm functions | Flue: 500 mm × 500 mm; when the average flue temperature exceeds 200°C, the equipment automatically triggers an alarm. |
| Test temperature range | (0~250)℃ |
| Temperature Measurement Configuration | 3 mm diameter K-type armored thermocouple, temperature measurement accuracy of 0.1°C. |
| Constant current flow | 10 m³/min |
| Differential pressure measurement | Measurement range: ±100 Pa; accuracy: 0.2% |
| Test gas source | Methane gas with a purity of 95% or higher |
| Methane flow meter | Flow range: 6–60 L/min; accuracy class 2.5 |
| Air flow meter | Flow range: (3–30) L/min, accuracy class 2.5 |
| Power supply | Three-phase AC 380V |
| Burn test duration requirements | The standard test duration is 10 minutes; the flame may be terminated early if sustained visible combustion occurs, or if the maximum average temperature exceeds 200°C. |
Related Product
HC-40 Concrete Multi-functional Strength Tester
The HC-40 concrete multi-functional strength tester is a high-performance testing device integrating multiple advanced technologies, specifically designed for evaluating the strength and quality of concrete.
FAQs
Customer Reviews
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.