SYA-14A Building Insulation Material Combustibility Performance Testing Apparatus (New Standard)
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
The building material combustibility test furnace is a highly precise, highly automated, safe, reliable, and easy-to-operate device with a broad range of applications and significant practical value. It provides robust assurance for building safety and offers critical support to research institutions and testing and certification bodies.
Combustion system simulations are used to conduct fire‑resistance tests on building materials under realistic fire conditions. During the test, the control system regulates the operation of the combustion apparatus according to the prescribed test parameters, while the measurement system continuously monitors and records the material’s performance throughout the combustion process. The building‑material combustibility test furnace, based on the German Kleinbrenner principle, subjects samples to a small vertical flame impingement; by comparing and analyzing the test data, it enables the assessment of the material’s flammability class and its combustion characteristics.
Product Features:
1. The operation design conforms to ergonomic principles; all tests are conducted via a touch-screen interface, featuring a high degree of automation, with the capability to store previous test results and retrieve historical data.
2. The servo‑motor‑driven test fixture features controllable automatic lifting and lowering.
3. The Bunsen burner is adjustable in both extension and retraction;
4.1.5 mm stainless steel sheet metal enclosure;
5. Double‑angled observation test with two tempered heat‑resistant glass doors (with lock), convenient and practical.
6. Automatic high-pressure ignition and long-lasting combustion;
7. The ignition source can automatically tilt to 45 degrees;
8. The flame height is adjusted via a precision regulating valve;
9. The sample holder can be moved vertically and horizontally;
10. Equipped with two types of specimen holders.
11. Flame measurement scale;
12. High degree of automation, with precise experimental data and easy operation;
Appearance and Structure:
The touch-screen‑controlled combustibility test furnace for building materials features a stainless steel cabinet and has been upgraded with a touch-screen interface, automated sample‑holding lift‑and‑lower functionality, and adjustable forward–rear positioning of the Bunsen burner. Its integrated design delivers a clean, elegant appearance and a compact, well‑thought‑out structure. The equipment comprises a control system, a combustion system, a measurement system, and a safety‑protection system. The control system manages overall operation and test‑process control; the combustion system simulates real‑world fire conditions to evaluate the combustibility of building materials; the measurement system continuously monitors and records data during testing; and the safety‑protection system ensures the safety and reliability of the testing process.
Reference standard:
Applicable Standard: ISO 11925-2:2002 E “Methods of test for the flammability of building materials”
Design Standard: GB/T 8626 “Test Method for Flammability of Building Materials”
Technical Specifications:
| Parameter Category | Parameter content |
| Ambient temperature | 15℃~25℃ |
| Relative humidity | ≤85% |
| Supply voltage | 220V/50Hz/100W |
| Combustible gas source | Commercial propane with a purity of ≥95%; Liquefied petroleum gas may be used as a substitute for standard testing (users are responsible for providing the gas supply and connecting fittings). |
| Standard flame application time for the Bunsen burner | 15s |
| Control method | Microcontroller control, digital display |
| Burner parameters | Burner orifice diameter: Φ0.17 mm; Flame length: 20 mm ± 1 mm; The burner can be tilted by 45°. |
| Flame Duration Range | Adjustable from 1 s to 99 s, with timing accuracy of ±0.2 s and an error margin of ±0.5 s. |
| Bottom vent | A horizontally mounted natural ventilation opening, composed of 5 cm × 5 cm square perforations in 1.5 mm-thick steel sheeting and 50 mm high, ensures uniform airflow through the opening. |
| Processing technology | Meticulous craftsmanship, with a solderless construction. |
| Touchscreen size | 7 inches |
| Touchscreen resolution | 800×480 |
| Communication interface | RS232, 3.3V CMOS/TTL, serial interface |
| Enclosure external dimensions | Width 930 × Depth 400 × Height 970 mm |
| Weight | 165kg |
Test procedure:
1. Sample Preparation:
Specimen shape and dimensions: The standard specimen size is 250 mm +0/−1 mm in length and 90 mm +0/−1 mm in width.
2. Sampling: Specimens with a nominal thickness not exceeding 60 mm shall be tested at their actual thickness. For specimens with a nominal thickness greater than 60 mm, the thickness shall be reduced to 60 mm on the unexposed face, and the test shall be conducted using a 60‑mm thickness. If this method of reducing the specimen dimensions is employed, the cut surface shall not be designated as the fire‑exposed face. For products whose standard production dimensions are smaller than the specimen dimensions, appropriately sized specimens shall be fabricated specifically for testing. The sampling methods and quantities are as follows:
1) For each ignition method, at least six representative product specimens shall be tested, and three specimens shall be cut from each specimen in both the longitudinal and transverse directions.
2) If the test specimen has an asymmetrical thickness, and both surfaces may be exposed to fire in actual applications, tests shall be conducted separately on each surface of the specimen.
3) If several surface areas of the product differ markedly, but each surface area meets the surface characteristics specified below, an additional set of tests shall be conducted to evaluate the product.
The product shall possess one of the following characteristics:
1. Flatten the fire-exposed surface;
2. If the surface of the product is irregular, but this irregularity is uniformly manifested across the entire fire-exposed surface, it may be regarded as a flat fire-exposed surface provided that the following requirements are met:
1) On the surface of a representative area measuring 250 mm × 250 mm, at least 50% of the surface shall have a vertical distance from the plane containing the highest point on the fire-exposed side not exceeding 6 mm.
2) For surfaces with gaps, cracks, or holes, the width of such gaps, cracks, or holes shall not exceed 6.5 mm, and their depth shall not exceed 10 mm; furthermore, their total surface area shall not exceed 30% of a representative 250 mm × 250 mm area on the fire-exposed surface.
3) If the product is edge-sealed on all sides during installation but can still be used without edge protection, tests shall be conducted separately on edge‑sealed and unsealed specimens.
3. Substrate
If the product is installed on a substrate under its intended service conditions, the test specimen shall be representative of the final application. Furthermore, the substrate shall be selected in accordance with EN 13238.
4. State Regulation
The test specimens and filter paper shall be conditioned in accordance with EN 13238.
5. Test Preparation
1) Under the condition of only igniting the burner and opening the exhaust hood, the air velocity in the control cabinet’s flue shall be (0.7 ± 0.1) m/s.
2) Remove the six specimens from the conditioning chamber and complete the test within 30 minutes. If necessary, the specimens may also be removed from the conditioning chamber and placed in the testing apparatus inside a sealed enclosure.
3) Place the specimen in the specimen holder so that its two edges and upper edge are enclosed by the holder, with the fire-exposed end positioned 30 mm from the bottom of the holder.
4) Press the “Start Test” button on the control panel; the burner will automatically move to the right. At this point, turn off the equipment power, adjust the burner angle to 45°, and use the edge‑ignition and surface‑ignition positioners to align the left–right position by adjusting the positioning ring on support rod 16. If vertical adjustment is required, press and hold the stop button 5 to energize the system, then rotate the up/down switch 13 to set the desired distance between the burner and the specimen.
5) Place two pieces of filter paper in the aluminum foil collection tray beneath the specimen; this procedure must be completed within 3 minutes prior to the test.
Test procedure:
1) After connecting the gas supply, open the gas supply valve and press the ignition button on the control panel. The equipment will automatically ignite the vertically oriented burner and wait until the flame stabilizes.
2) Adjust the flame regulator 14 and measure the flame height using a flame gauge; the flame height shall be (20 ± 1) mm. To ensure test accuracy, the flame height must be measured before each ignition of the specimen.
3) Adjust the burner angle to 45°, press the Start Test button, and the burner will automatically ignite and begin moving to the right. When it reaches the position set in the “Test Preparation” mode, the device will automatically initiate the flame‑exposure duration.
4) When the set ignition time is reached, the burner automatically shuts off and retracts; at this point, the flame-holding time timer is automatically started.
5) When the afterflame of the specimen extinguishes or the highest point of the afterflame reaches the designated mark, press the pause button to stop the afterflame duration timer.
6) Press the reset button on the control panel; all test data will be cleared, and the system will be ready for testing the next specimen.
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords:
SYA-14A Building Insulation Material Combustibility Performance Testing Apparatus (New Standard)