Lb-DC2A Hollow Vacuum Glass U-Value Heat Transfer Coefficient Tester
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
This instrument is designed and manufactured in accordance with the standards GB/T 22476 for the calculation and determination of the steady-state U-value (thermal transmittance) of insulating glass, and GB/T 10295-2008 (Determination of Steady-State Thermal Resistance and Related Properties of Thermal Insulation Materials—Hot‑Box Method). Both measurement and control are computer‑controlled, enabling fully automated operation.
It is applicable to manufacturers of insulating glass materials, relevant quality inspection agencies, organizations, higher education institutions, and research institutes and other scientific research entities.
Working principle:
Under steady-state conditions, within the central measurement region of the guarded hot plate apparatus, a one-dimensional steady heat flow—similar to that existing in an infinitely large plane with two parallel isothermal surfaces—is established in a uniform, plate‑shaped specimen having parallel faces.
Equipment composition:
It employs the dual-specimen guarded hot plate method (GB 10294, GB/T 22476) and comprises a microcomputer‑based automatic control system, a metered heating unit, a cold plate unit, a protective enclosure, an external protective enclosure, a measurement system, a clamping system, and a refrigeration mechanism.
1. Microcomputer Automatic Control System:
The computer’s output signals are processed via I/O and D/A conversion to control the corresponding actuators, enabling functions such as temperature control, computation, temperature data acquisition, printing of test reports, and display of process curves. The human–machine interface window displays the temperature values for each zone and includes a self-diagnostic capability.
2. Metering and Heating Unit:
A high‑thermal‑conductivity plate is used as the heating panel; its superior thermal conductivity ensures more uniform surface temperatures and lower thermal inertia, thereby enhancing the accuracy of measurement results.
3. Cold Plate Unit:
A constant-temperature water bath is used to regulate the temperatures of the two cold plates; the cold‑plate temperature is programmable and automatically controlled by a microcomputer, which helps maintain a uniform temperature difference between the two sides.
4. Protective Unit:
It employs the same panel material as the metered heating unit, enabling precise control of the temperature difference between the two sides and reducing test errors.
5. External Protection Unit:
A protective sleeve made of cork is used as the outer shielding unit, stabilizing the experimental environmental conditions and thereby enhancing test accuracy.
6. Measurement System:
By employing the more stable U.S.-made Dallas DS18B20 digital temperature sensor and a high-precision DC power sensor, data acquisition accuracy is significantly enhanced.
7. Pressing System:
Employing pneumatic technology, the system uses a cylinder to automatically clamp the specimen, eliminating the need for manual adjustment of clamping force and ensuring convenient specimen loading.
8. Refrigeration System:
It enables rapid cooling of the cold plate and measurements where the specimen’s average temperature remains below ambient, thereby expanding the measurement range and eliminating dependence on ambient temperature.
Reference standard:
GB/T 10294 “Determination of Steady-State Thermal Resistance and Related Properties of Thermal Insulation Materials”
GB/T 22476 “Calculation and Determination of the Steady-State U-Value (Thermal Transmittance) of Insulating Glass”
Technical Specifications:
| Parameter Category | Parameter content |
| Specimen specifications | 800mm×800mm×H(10~120) mm |
| Heat transfer coefficient measurement range | (0.25-4.5)W/(m²•K) |
| Heat transfer coefficient measurement accuracy | ±3% |
| Cold plate temperature | (-5-50)°C |
| Hot plate temperature | (10-80)℃ |
| Repeatability of thermal conductivity measurement | ±1% |
| Temperature measurement value | Cold plate set temperature: 2.5℃; Hot plate set temperature: 17.5℃ |
| Temperature resolution | 0.01℃ |
| Laboratory temperature | (23±2)°C |
| Laboratory humidity | (40–60)%RH |
| Power supply voltage | 220V, 5kW, three-phase five-wire system |
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords:
Lb-DC2A Hollow Vacuum Glass U-Value Heat Transfer Coefficient Tester