JBS-300B Touchscreen-Controlled Metal Pendulum Impact Testing Machine
Category:
Keywords:
E-mail:
WhatsApp:
Description
Product Introduction:
The JBS-300B touchscreen‑controlled metal pendulum impact testing machine is a next‑generation pendulum impact tester. It is used to evaluate the impact resistance of metallic materials under dynamic loading, thereby assessing their performance under such conditions. This equipment serves as a testing instrument in metallurgical and mechanical manufacturing facilities, as well as a research tool for developing new materials in scientific research institutions.
The JBS-300B touch-screen‑controlled metal pendulum impact testing machine is a semi‑automatic, touch‑screen‑based instrument that employs microcomputer control. It enables fully automated operations—including pendulum raising, impact application, measurement, data processing, on‑screen digital display, and printing—delivering high operational efficiency and exceptional test accuracy. After each impact test, the remaining energy automatically raises the pendulum, preparing the machine for the next trial; its simple operation further enhances productivity. This equipment particularly excels in laboratories conducting continuous impact tests, as well as in industries such as metallurgy and mechanical manufacturing that perform large volumes of impact testing. The computer can calculate and display, in digital form, the material’s impact energy absorption, the pendulum lift angle, and the average test values.
Reference standard:
GB/T 3808-2018 “Verification of Pendulum Impact Testing Machines,”
GB/T 229-2020 “Metallic Materials — Charpy Pendulum Impact Test Method”
GB/T 18658-2018 “Charpy V-notch Standard Specimens for Verification of Pendulum Impact Testing Machines”
ISO 148 “Charpy Impact Test for Metallic Materials”
ASTM E23, “Standard Test Method for Notched Bar Impact Testing of Metallic Materials”
Product Features:
1. Remote data transmission can also be implemented according to user requirements.
2. The testing machine features a single-column frame with a cantilever‑type pendulum mounting. The pendulum is designed as a C‑shaped mass, ensuring accurate impact centering and precise pendulum torque.
3. The impact blade is secured with screws, making replacement simple and convenient.
4. Equipped with a safety pin and a safety guard mesh;
5. Touchscreen control: the entire test sequence—gripping and positioning, impact, automatic pendulum release, and subsequent impacts—is executed according to the programmed instructions.
Technical Specifications:
| Parameter Category | Parameter content |
| Pendulum pre-raise angle | 150° |
| Distance from the pivot axis center to the impact point | 750mm |
| Impact velocity | 5.2m/s |
| Specimen support span | 40mm |
| Jaw fillet | R1-1.5mm |
| Impact blade fillet | R2-2.5mm |
| Impact blade thickness | 16mm |
| Angular accuracy | ±0.1° |
| Specimen dimensions | 10×10×55mm |
| Pendulum torque | M300=160.7696 N·m, M150=80.3848 N·m |
| Total weight of the testing machine | Approximately 500 kg |
| Power supply | Three-phase AC, 380 V ±10%, 50 Hz, 5 A |
| Impact capacity range and display accuracy | |
| Energy range | 0-300J, 0-150J |
| The scale division value of each small division on the dial | 0–300 J: 0.5 J; 0–150 J: 0.25 J |
| Touchscreen display resolution | 0.01J |
| Product Description | Display symbol GB/T 229-2020 “Metallic Materials — Charpy Pendulum Impact Test Method” |
Main configuration:
| Serial number | Name | Specification | Quantity |
| 1 | Host | 450Kg | 1 unit |
| 2 | Pendulum | About 300 J | 1 pair |
| Small swing 150J | 1 pair | ||
| 3 | Span Template | L=40 | 1 item |
| 4 | Specimen centering block | L=40 (V-shaped) | 1 item |
| 5 | Return and sales device | Traction Electromagnet Control | 1 set |
| 6 | Hanging and swinging device | Valve solenoid control | 1 set |
| 7 | Motor | 250W | 1 set |
| 8 | Printer | Thermal printer | 1 set |
| 9 | Software | In-house production | 1 set |
| 10 | PLC | In-house production | 1 set |
| 11 | Impact blade | R2 (National Standard) | 1 item |
| 12 | Impact blade (optional) | R8 (US standard) | 1 item |
| 13 | Dismantling tool | For hammer replacement only | 1 item |
| 14 | Anchor bolt | S=250 | 4 sets |
| 15 | Adjusting wedge | Adjust the machine's level. | 4 pieces |
| 16 | Hex key wrench | S=12 | 1 piece |
| 17 | Jaw (including Jaw holder) |
R1-1.5mm | 1 pair |
| 18 | Protective Net | Semi-enclosed | 1 set |
| 19 | Hand Control Box | In-house production | 1 pair |
| 20 | Instruction Manual | In-house production | Combined into 1 portion |
| 21 | Certificate of Conformity | In-house production | |
| 22 | Packing List | In-house production |
Measurement and Control Section Description :
1. Bilingual interface: Supports both Chinese and English as operating languages, with the option to switch between them before entering the experimental interface.
2. Semi-automatic operation: During testing, the pendulum is manually raised first; after completion, the specimen is manually released, followed by pin retraction and impact. Once the impact is finished, the equipment automatically retrieves the pendulum. After each test, the system’s display area shows the impact energy and impact toughness. Three tests constitute one set; upon completion of the set, the system automatically calculates the average of the three impact energies.
3. Storage Function: It can store 100 sets of experimental data, including the test name, raw test values, average values, test time, and other relevant information.
4. Printing Function: (Optional) Prints the current test data via a miniature printer.
5. Multi-level energy: The device supports multiple hammer energy levels.
6. It can be connected to a USB flash drive to enable computer-based printing of reports.
7. The equipment employs a Panasonic PLC from Japan as the lower-level controller and a touch screen as the upper-level controller. The upper-level program is developed in VB, utilizing RS‑232 communication to facilitate data exchange and command transmission between the two levels. This fully leverages the powerful computing capabilities of a PC for data processing, report generation, and other functions. A high-precision rotary encoder is used to acquire the pendulum’s real-time position, enabling accurate measurement of impact energy absorption. The system features high reliability, stability, and precise data accuracy.
Scene Description:
The local display interface comprises a total of six screens: the startup screen, the control screen, the storage recall screen, the password entry screen, the system settings screen, the alarm screen, and the print screen, with six versions available in both Chinese and English.

(1) Test Startup Interface
Select the Chinese or English system before entering the trial.


(2) Chinese–English test interface
The device’s primary user interface, where various device operations are performed.

(3) Sample Information Input Interface
This interface is used to enter the basic information of the specimen, preparing for the calculation of impact toughness.


(4) Test Results Printing Interface
After the test is completed, click the Print button on the specimen information screen to display the print‑out report preview. Then, in the print preview, click the Print button to generate the test results. (A micro‑printer must be connected externally before printing.)


(5) The system parameters enter the password input interface.
To access the system parameter debugging interface, you must enter the debugging password (Password: 123456).


(6) System Parameter Debugging Interface
Please do not access the system parameter interface unless necessary. All parameters have been properly configured at the factory; do not modify them arbitrarily, as this may compromise the accuracy of your test results.


(7) Storage Call Interface
This interface is the historical record query screen, allowing you to view the most recent one hundred sets of test results.
Operating Instructions
This instruction is provided using the Chinese interface as an example; the functions, locations, and operational procedures of the English interface are identical to those of the Chinese interface.
Experimental Procedure:

Tap to enter the system from the boot screen, and you’ll be taken to the device’s operation interface.
Note: Perform a zero-point calibration before operation.


The functions of the operation screen are as follows:
Swing Setting: Press this button to slowly raise the pendulum until it reaches the upper limit, at which point it will stop automatically and the safety pin will pop out.
Retraction: Press this button to safely retract the safety pin, preparing for the impact and pendulum release. This operation must be performed before initiating the impact or pendulum‑release sequence. After retraction, do not approach the pendulum’s swing path to prevent accidents.
Impact: Press this button to allow the pendulum to fall freely and strike the specimen; after the impact, it will automatically return to its initial position, ready for the next test.
Release pendulum: Press this button once, and the pendulum will slowly swing down.
It automatically stops when it reaches the lowest point.
Small hammer: Used to display the current energy level; tap to switch between energy levels. During testing, be sure to match it with the corresponding large hammer on the device.
System Parameters: Press this button to access the password screen. If the password is entered correctly, the system will proceed to the parameter‑setting screen. Do not modify the system parameters arbitrarily to avoid compromising the accuracy of the test results.
Zero-point confirmation: When the pendulum has come to rest and the angle reading is not 0.00, click this button to perform zero-point calibration and eliminate accumulated error.
Specimen Information: Click to access the specimen information screen. Before testing, enter the specimen details to prepare for calculating the impact toughness. To print the test results, press the Print button on the test information screen.
Storage Invocation: Tap to access the storage invocation screen, where you can save the current test results for future retrieval; the storage screen also allows you to retrieve and print the print history.
Result Saving: After completing each test group (3 specimens), you must click the Save Results button; otherwise, the results will not be stored in the history.
Test procedure:
1. Take the pendulum; when the pendulum reaches its highest position, the safety pin automatically pops out.
2. Manual feeding: Manually place the specimen on the stable platform.
3. Return and sale; safe return to stock, in preparation for a surge in demand.
4. Impact: Press the impact button to allow the pendulum to fall freely and fracture the specimen, then automatically return to the maximum reverse position to re‑hang the pendulum, at which point the safety pin is ejected.
5. Manually feed the second specimen for testing.
After each test is completed, the system’s display area will show the test results. Repeat the above steps three times to complete one test cycle; once the cycle is finished, the system automatically calculates the average of the three impact energies. For the next impact, the data is automatically reset, and new test values are recorded.
Impact Energy Calibration:


Impact Energy Calibration Interface
Adjustment method:
1. First, level the equipment so that, when the pendulum is at rest, it is perpendicular to the impact surface of the device.
2. Secure the equipment with anchor bolts, then pour concrete around the equipment base.
3. After the cement has set, begin adjusting the impact energy.
4. Adjust the pendulum torque so that the free‑fall impact energy of the large hammer is 300 J and that of the small hammer is 150 J.
5. Raise the pendulum, then press the detent button, followed by a pointer‑friction click and an impact click. Repeat this twice; after completing the sequence, perform one final pointer‑friction click to deactivate the pointer‑friction test. (Note: After deactivation, the font of the pointer‑friction button will return to its default appearance.)
6. Raise the pendulum, then press the detent button, followed by clicking “System Friction” and then “Impact.” Run the impact testing machine through ten empty strikes to automatically calculate the respective error values. Once the pendulum has returned to its initial position, press the “System Friction” button (i.e., change the text from red to black).
Related Product
WSC-300 Microcomputer-Controlled Steel Strand Stress Relaxation Testing Machine
The WSC-300 microcomputer-controlled steel strand stress relaxation testing machine employs servo control technology and computer-based data acquisition and processing, enabling closed-loop control and automated testing. It comprises four main components: the testing frame, the servo control system, the measurement and control system, and the test fixtures. With a maximum test force of 300 kN, the machine achieves an accuracy class better than 0.5.
YLZ-100 Microcomputer-Controlled Electro-Hydraulic Servo Curbstone Flexural Testing Machine
The YLZ-100 concrete curbstone flexural‑compressive testing machine is used to determine the flexural strength and flexural load of linear curbstones with a length of 1000 mm, as well as the compressive strength of curved curbstones and L‑shaped curbstones with a straight cross‑section. In accordance with JC/T 899‑2016 Concrete Curbstones, it can also be employed to conduct experimental studies on the flexural and compressive strengths of other materials.
The microcomputer-controlled high‑ and low‑temperature electronic universal testing machine consists of the testing machine mainframe, fixtures, a high‑ and low‑temperature chamber, and computer software. The temperature chamber is slid into the mainframe; after opening the chamber door, the specimen is secured in the dedicated fixture. The chamber then heats or cools until the specified temperature is reached.
WDW—Dual-Column Microcomputer-Controlled Electronic Universal Tensile Testing Machine (20 kN)
This machine can perform tests such as tensile, compressive, flexural, tear, 90° peel, 180° peel, shear, adhesion, pull-out force, and elongation at break on rubber, plastics, foamed materials, synthetic resins, films, alloy materials, and other non-metallic and metallic materials.
FAQs
Customer Reviews
Southeast Asia Rubber & Polymer Factory|Purchase: Vicat Softening Point & Tensile Testing Machine
2026.06.05
★★★★★
Middle East Construction Lab|Purchase: Universal Electronic Testing Machine & Geotextile Test Equipment
2026.06.05
★★★★★
European Plastic Pipe Manufacturer|Purchase: Ring Stiffness & Hydrostatic Burst Tester
2026.06.05
★★★★★
Consult
We will contact you within one working day. Please pay attention to your email.
Keywords: